You are here Insinerator

Incinerator - PD. Karya Mitra Usaha

Insinerator

Incinerator Kecil Untuk Sampah Umum
1. Incinerator Single Burner w/scrubber

Incinerator Single Burner
Jumlah Burner : 1 unit
Kapasitas up to 5kg/batch
Ukuran dia 60 x 100 cm
Diameter cerobong 35 cm / 25cm
Bahan Bakar : Gas atau bisa Solar (harus dipilih)
Temperature : 400 - 800 Deg C , Tergantung kalori, bisa sampai 1200 deg C
Tinggi Cerobong dari tanah : 4 m, bisa extend
Dilengkapi water scrubber
Wall insulation : Castable
Panel : Electrical Panel, temp copntroller

2.Incinerator Single Burner w/scrubber

Incinerator Single Burner
Jumlah Burner : 2 unit
Kapasitas up to 5kg/batch
Ukuran dia 76 x 100 cm
with double shell, steel
Diameter cerobong 40 cm / 25 cm
Bahan Bakar : Gas atau bisa Solar (harus dipilih)
Temperature 1st Burner : 400 - 800 Deg C , Tergantung kalori
Temperature 1st Burner : 600 - 1100 Deg C
Tinggi Cerobong dari tanah : 4 m, bisa extend
Dilengkapi water scrubber
Wall insulation : Castable
Panel : Electrical Panel, temp conntroller

3.Incinerator Doublee Burner w/scrubber

Incinerator Double Burner
Jumlah Burner : 2 unit
Kapasitas up to 5kg / batch
Ukuran Primary Chamber dia 76 x 100 cm
Ukuran secondary Chamber dia 40 x 70 cm
Diameter cerobong 40 cm/25cm
Bahan Bakar : Gas atau bisa Solar (harus dipilih)
Temperature 1st Burner : 400 - 800 Deg C , Tergantung kalori
Temperature 1st Burner : 600 - 1100 Deg C
Tinggi Cerobong dari tanah : 4 m, bisa extend
Dilengkapi water scrubber
Wall insulation : Castable
Panel : Electrical Panel, temp conntroller

4.Incinerator Doublee Burner w/scrubber

Incinerator Double Burner
Jumlah Burner : 2 unit
Kapasitas up to 5kg / batch
Ukuran Incinerator Chamber dia 76 x 120 cm
Diameter cerobong 40 cm/25cm
Bahan Bakar : Gas atau bisa Solar (harus dipilih)
Temperature 1st Burner : 400 - 800 Deg C , Tergantung kalori
Temperature 1st Burner : 600 - 1100 Deg C
Tinggi Cerobong dari tanah : 4 m, bisa extend
Dilengkapi water scrubber
Wall insulation : Castable
Panel : Electrical Panel, temp conntroller

5.Incinerator Doublee Burner w/scrubber

Incinerator Double Burner
Jumlah Burner : 2 unit
Kapasitas up to 5kg / batch
Ukuran Incinerator Chamber 75 x 120 cm
Diameter cerobong 40 cm/25cm
Bahan Bakar : Gas atau bisa Solar (harus dipilih)
Temperature 1st Burner : 400 - 800 Deg C , Tergantung kalori
Temperature 1st Burner : 600 - 1100 Deg C
Tinggi Cerobong dari tanah : 4 m, bisa extend
Dilengkapi water scrubber
Wall insulation : Castable, Fire Brick dan Insulation Brick
Panel : Electrical Panel, temp conntroller

Single Burner Incinerator
1. Single Burner Incinerator Cap. : 5 to 9 kg/jam (70 kg/hari) c/w scrubber

Type of Waste : Laboratory Waste / Medical Waste
Single Burner Incinerator without Burner cap 5 to 9 kg/hour
Operating time : 8 hour /day
Dimension :
Chamber Dimension : 50 x 50 x 80 cm
Chamber Volume : 0.2 m3 ( 9 kg/hour)
Incinerator Body dimension : LxWxH :80 x 80 x 100 cm
Burner : 4-6 liter /jam, Light Oil Burner 1 unit
Chamber Temperature : ± 600 to 800 Deg C
Chamber Pressure : Negatif
Exhaust Stack Dia 250/150 mm, height 3 m , with high temp coating
Refractory Construction :
For Bottom floor ; Fire Clay Brick and Fire Brick
For Shell Plate ; Ceramic Fiber and Fire Brick
For Roof, Burner Port, Door and Nozzle ; Castable
Body Construction :
For Bottom, Shell and Roof Material from Mild Steel thk 3mm
For Joint Flange 10 mm thickness
For Structure Material : Shape and Mild Steel
For Lifter Padeyes thk 12mm
Coating : Epoxy Coating
Air Blower 2.5", 220 Volt, 50/60 Hz, 260 Watt
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Control System :
- Electronic Control Panel
- Temperature Control : Digital
- Thermocouple : Type – K.
Power Requirement : 1.3 kW / 220 Volt / 1phase / 50Hz
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 3 x 3 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%
Total Empty Weight ± 830 kg

2.Single Burner Incinerator Cap. : 10 to 15 kg/jam (120 kg/hari) c/w scrubber 

Type of Waste : Laboratory Waste / Medical Waste
Single Burner Incinerator without Burner cap 10 to 15 kg/hour
Operating time : 8 hour /day
Dimension :
Chamber Dimension : minimum 63 x 64 x 80 cm
Chamber Volume : 0.32 m3 ( 10 to 15 kg/hour)
Incinerator Body dimension : LxWxH : 100 x 90 x 110 cm
Oil Burner : 5 - 10 liter /jam, Light Oil Burner 1 unit
Chamber Temperature : ± 600 to 800 Deg C
Chamber Pressure : Negatif
Exhaust Stack Dia 250/200 mm, height 4 m , with high temp coating
Refractory Construction :
For Bottom floor ; Fire Clay Brick and Fire Brick
For Shell Plate ; Ceramic Fiber and Fire Brick
For Roof, Burner Port, Door and Nozzle ; Castable
Body Construction :
For Bottom, Shell and Roof Material from Mild Steel thk 3mm
For Joint Flange 10 mm thickness
For Structure Material : Shape and Mild Steel
For Lifter Padeyes thk 12mm
Coating : Epoxy Coating
Air Blower 2.5", 220 Volt, 50/60 Hz, 260 Watt
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 1.3 kW / 220 Volt / 1phase / 50Hz
Control System :
- Electronic Control Panel
- Temperature Control : Digital
- Thermocouple : Type – K.
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 3.2 x 3.2 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%
Total Empty Weight ± 1,280 kg

3. Single Burner Incinerator Cap. : 17 to 25 kg/jam (200 kg/hari) c/w scrubber

Type of Waste : Laboratory Waste / Medical Waste
Single Burner Incinerator without Burner cap 17 to 25 kg/hour
Operating time : 8 hour /day
Dimension :
Chamber Dimension : 80 x 80 x 90 cm
Chamber Volume : 0.58 m3 ( 17 to 25 kg/hour)
Incinerator Body dimension : LxWxH : 100 x 100 x 120 cm
Oil Burner : 5 - 12 liter /jam, Light Oil Burner 1 unit
Chamber Temperature : ± 600 to 800 Deg C
Chamber Pressure : Negatif
Exhaust Stack Dia 250/200 mm, height 4 m , with high temp coating
Refractory Construction :
For Bottom floor ; Fire Clay Brick and Fire Brick
For Shell Plate ; Ceramic Fiber and Fire Brick
For Roof, Burner Port, Door and Nozzle ; Castable
Body Construction :
For Bottom, Shell and Roof Material from Mild Steel thk 3mm
For Joint Flange 10 mm thickness
For Structure Material : Shape and Mild Steel
For Lifter Padeyes thk 12mm
Coating : Epoxy Coating
Air Blower 2.5", 220 Volt, 50/60 Hz, 260 Watt
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 1.3 kW / 220 Volt / 1phase / 50Hz
Control System :
- Electronic Control Panel
- Temperature Control : Digital
- Thermocouple : Type – K.
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 3.5 x 3.5 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%
Total Empty Weight ± 1,360 kg

Double Burner Incinerator
1. Incinerator Cap. 9 kg/batch Double Burner with Scrubber (Skitar 75 kg/hari atau lebih )

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domesti Waste / Sampah Bukan B3
Incinerator Capacity : 60 Liter = 9 kg/batch Multiple Chamber
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 0.2 m³ ( 55 cm x 55 cm x 70 cm)
- Second chamber : 0.1 m³ ( L. 31 cm x W. 55 cm x. H.70 cm)
Incinerator Dimension (Outter) : LxWxH : 129 x 86 x 85 cm
Burner :
- 1st Burner : 4 – 6 liter / hour, Light Oil Burner, Qty : 1 unit
- 2nd Burner : 4 – 6 liter / hour, Light Oil Burner, Qty : 1 unit
Motor 220V / 50 Hz/ 1 Phase: 150 Watt x 2 : 300 Watt
Chamber Temperature :
- 1st Chamber : 600 - 800°C
- 2nd Chamber : 800- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
- Diameter : 400mm (1st Stack), Ø200 mm (2nd Stack)
- Height : ±8 m.from ground level
- Sampling Port Ø3”
- Coating : High Temp.Paint
Insulation and Refractory Construction Materials :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
- Ceramic Fibre, 128 kg/m³
- Rockwool,60 kg/m³
- Glaswool, 20 kg/m³
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate thickness 3 mm ,Mild Steel
- Joint Flange thickness 10 mm
- Burner Port thickness 6 mm
- Plenum Plate thickness 3 mm
- Structure UNP 80 & UNP 50
- Lifter thickness 12 mm
- Coating : Epoxy Paint
FDF Blower : Sentrifugal 3", 370 Watt , 3000 rpm, 1 unit
Diesel Oil Fuel Consumption : average12 liter / hour
Fuel Tank :
- Tank Capacity 150 ltr
- Material Tank : Mild Steel plate t. 4 mm
- Level Control
- Drain Port
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 1,2 kW / 220 Volt / 1phase / 50Hz
Control System :
- ELC
- Temperature Control : Digital
- Thermocouple : Type – K.
- Limit Switch
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 3.5 x 4.5 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%

2.Incinerator Cap.15 kg/batch Double Burner with Scrubber (Skitar 120 kg/hari atau lebih )

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domesti Waste / Sampah Bukan B3
Incinerator Capacity : 105 Liter = 15 kg/batch Multiple Chamber
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 0.35 m³
- Mixing Room : 0.1 m³
- Second Chamber : 0.15 m³
Incinerator Dimension (Outter) : L:142 X W:99 X H:98 cm
Burner :
- 1st Burner : 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
- 2nd Burner : 5 –10 liter / hour, Light Oil Burner, Qty : 1 unit
Motor 220V / 50 Hz/ 1 Phase: 150 Watt x 2 : 300 Watt
Chamber Temperature :
- 1st Chamber : 600 - 800°C
- 2nd Chamber : 800- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
- Diameter : 450mm (1st Stack), Ø200 mm (2nd Stack)
- Height : ±8 m.from ground level
- Sampling Port Ø3”
- Coating : High Temp.Paint
Insulation and Refractory Construction Materials :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
- Ceramic Fibre, 128 kg/m³
- Rockwool,60 kg/m³
- Glaswool, 20 kg/m³
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate thickness 3 mm ,Mild Steel
- Joint Flange thickness 10 mm
- Burner Port thickness 6 mm
- Plenum Plate thickness 3 mm
- Structure UNP 80 & UNP 50
- Lifter thickness 12 mm
- Coating : Epoxy Paint
FDF Blower : Sentrifugal 3", 370 Watt , 3000 rpm, 1 unit
Diesel Oil Fuel Consumption : average15 liter / hour
Fuel Tank :
- Tank Capacity 200 ltr
- Material Tank : Mild Steel plate t. 4 mm
- Level Control
- Drain Port
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 1,2 kW / 220 Volt / 1phase / 50Hz
Control System :
- ELC
- Temperature Control : Digital
- Thermocouple : Type – K.
- Limit Switch
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 3.8 x 4.8 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%

3. Incinerator Cap.20 kg/Batch Double Burner with Scrubber (Approx 180 kg/hari atau lebih )

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domesti Waste / Sampah Bukan B3
Incinerator Capacity : 20 kg/batch, Multiple Chamber
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 0.5 m³
- Mixing Room : 0.1 m³
- Second Chamber : 0.2 m³
Incinerator Dimension (Outter) : L:150 X W:120 X H:160 cm
Burner :
- 1st Burner : 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
- 2nd Burner : 5 –10 liter / hour, Light Oil Burner, Qty : 1 unit
Motor 220V / 50 Hz/ 1 Phase: 150 Watt x 2 : 300 Watt
Chamber Temperature :
- 1st Chamber : 600 - 800°C
- 2nd Chamber : 800- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
- Diameter : 450mm (1st Stack/Scrubber ), Ø250 mm (2nd Stack)
- Height : ±8 m.from ground level
- Sampling Port Ø3”
- Coating : High Temp.Paint
Insulation and Refractory Construction Materials :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
- Ceramic Fibre, 128 kg/m³
- Rockwool,60 kg/m³
- Glaswool, 20 kg/m³
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate thickness 3 mm ,Mild Steel
- Joint Flange thickness 12 mm
- Burner Port thickness 6 mm
- Plenum Plate thickness 3 mm
- Structure UNP 80 & UNP 50
- Lifter thickness 12 mm
- Coating : Epoxy Paint
FDF Blower : Sentrifugal 3", 370 Watt , 3000 rpm, 1 unit
Diesel Oil Fuel Consumption : average15 liter / hour
Fuel Tank :
- Tank Capacity 250 ltr
- Material Tank : Mild Steel plate t. 4 mm
- Level Control
- Drain Port
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 1,2 kW / 220 Volt / 1phase / 50Hz
Control System :
- ELC
- Temperature Control : Digital
- Thermocouple : Type – K.
- Limit Switch
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 4 x 5 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%

4. Incinerator Cap.30 kg/Batch Double Burner with Scrubber (Approx 240 kg/hari atau lebih )

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domesti Waste / Sampah Bukan B3
Incinerator Capacity : 30 kg/Batch, Multiple Chamber
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 1.0 m³
- Mixing Room : 0.1 m³
- Second Chamber : 0.2 m³
Incinerator Dimension (Outter) : L:180 X W:140 X H:160 cm
Burner :
- 1st Burner : 5 – 10 liter / hour, Light Oil Burner, Qty : 1 unit
- 2nd Burner : 5 –10 liter / hour, Light Oil Burner, Qty : 1 unit
Motor 220V / 50 Hz/ 1 Phase: 150 Watt x 2 : 300 Watt
Chamber Temperature :
- 1st Chamber : 600 - 800°C
- 2nd Chamber : 800- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exhaust Stack :
- Diameter : 450mm (1st Stack/Scrubber), Ø250 mm (2nd Stack)
- Height : ± 10 m.from ground level
- Sampling Port Ø3”
- Coating : High Temp.Paint
Insulation and Refractory Construction Materials :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
- Ceramic Fibre, 128 kg/m³
- Rockwool,60 kg/m³
- Glaswool, 20 kg/m³
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate thickness 3 mm ,Mild Steel
- Joint Flange thickness 12 mm
- Burner Port thickness 6 mm
- Plenum Plate thickness 3 mm
- Structure UNP 80 & UNP 50
- Lifter thickness 12 mm
- Coating : Epoxy Paint
Blower : Sentrifugal 3", 370 Watt , 3000 rpm, Qty 2 unit
atau sentrifugal 6-12 mmAg, Capacity 14 m3/min, Qty 2 unit
Diesel Oil Fuel Consumption : average 15~20 liter / hour
Fuel Tank :
- Tank Capacity 250 ltr
- Material Tank : Mild Steel plate t. 4 mm
- Level Control
- Drain Port
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 1,5 kW / 220 Volt / 1phase / 50Hz
Control System Manual and Automatic:
- ELC
- Temperature Control : Digital
- Thermocouple : Type – K.
- Limit Switch
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 4 x 5.5 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%

5. Incinerator Cap.50 kg/Batch (0,5m3/batch) Double Burner with Scrubber (Approx 450 kg/hari atau lebih )

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domesti Waste / Sampah Bukan B3
Incinerator Capacity : 50 kg/Batch, Multiple Chamber
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 1.7 m³
- Mixing Room : 0.4 m³
- Second Chamber : 1.0 m³
Incinerator Dimension (Outter) : L:210 X W:150 X H:190 cm
Burner :
- 1st Burner : 10 – 20 liter / hour, Light Oil Burner, Qty : 1 unit
- 2nd Burner : 10 –20 liter / hour, Light Oil Burner, Qty : 1 unit
Motor 220V / 50 Hz/ 1 Phase: 250 Watt x 2 : 500 Watt
Chamber Temperature :
- 1st Chamber : 600 - 800°C
- 2nd Chamber : 600- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exhaust Stack :
- Diameter : 450mm (1st Stack /Scrubber ), Ø250 mm (2nd Stack)
- Height : ±12 m.from ground level
- Sampling Port Ø3”
- Coating : High Temp.Paint
Insulation and Refractory Construction Materials :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
- Ceramic Fibre, 128 kg/m³
- Rockwool,60 kg/m³
- Glaswool, 20 kg/m³
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate thickness 4 mm ,Mild Steel
- Joint Flange thickness 12 mm
- Burner Port thickness 8 mm
- Plenum Plate thickness 3 mm
- Structure UNP 80 & UNP 50
- Lifter thickness 12 mm
- Coating : Epoxy Paint
FDF Blower : Sentrifugal 3"&4" , 370 & 550 Watt , 3000 rpm
atau sentrifugal 6-12 mmAg, Capacity 14 m3/min, Qty 1 unit RB1
sentrifugal 8-25 mmAg, Capacity 25 m3/min, Qty 1 unit RB2
Diesel Oil Fuel Consumption : average 20 liter / hour
Fuel Tank :
- Tank Capacity 300 ltr
- Material Tank : Mild Steel plate t. 4 mm
- Level Control
- Drain Port
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 2 kW / 220 Volt / 1phase / 50Hz
Control System :
- ELC
- Temperature Control : Digital
- Thermocouple : Type – K.
- Limit Switch
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 6 x 8 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%

6. Incinerator Cap.75 kg/Batch Double Burner with Scrubber (Approx 800 kg/hari atau lebih )

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domesti Waste / Sampah Bukan B3
Incinerator Capacity : 75 kg/Batch, Multiple Chamber
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 2.2 m³
- Mixing Room : 0.5 m³
- Second Chamber : 1.2 m³
Incinerator Dimension (Outter) : L:280 X W:150 X H:200 cm
Burner :
- 1st Burner : 10 – 15 liter / hour, Light Oil Burner, Qty : 1 unit
- 2nd Burner : 10 –20 liter / hour, Light Oil Burner, Qty : 1 unit
Motor 220V / 50 Hz/ 1 Phase: 150-250 Watt x 2 : 500 Watt
Chamber Temperature :
- 1st Chamber : 600 - 800°C
- 2nd Chamber : 800- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exhaust Stack :
- Diameter : 450mm (1st Stack/Scrubber), Ø250 mm (2nd Stack)
- Height : ±12 m.from ground level
- Sampling Port Ø3”
- Coating : High Temp.Paint
Insulation and Refractory Construction Materials :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
- Ceramic Fibre, 128 kg/m³
- Rockwool,60 kg/m³
- Glaswool, 20 kg/m³
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate thickness 4 mm ,Mild Steel
- Joint Flange thickness 12 mm
- Burner Port thickness 8 mm
- Plenum Plate thickness 3 mm
- Structure UNP 80 & UNP 50
- Lifter thickness 12 mm
- Coating : Epoxy Paint
FDF Blower : Sentrifugal 4", 550Watt , 3000rpm : 2 unit (1100Watt)
atau sentrifugal 8-25 mmAg, Capacity 25 m3/min, Qty 2 unit RB1/RB2
Diesel Oil Fuel Consumption : average 35 liter / hour
Fuel Tank :
- Tank Capacity 400 ltr
- Material Tank : Mild Steel plate t. 4 mm
- Level Control
- Drain Port
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 2.2 kW / 380 Volt / 1phase
Control System :
- ELC
- Temperature Control : Digital
- Thermocouple : Type – K.
- Limit Switch
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 6 x 9 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%

7.Incinerator Cap.100 kg/Hour ( 1m3/batch) Double Burner with Scrubber (Approx 800 kg/hari atau lebih )

Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domesti Waste / Sampah Bukan B3
Incinerator Capacity : 100 kg/Batch, Multiple Chamber
Operation Time : 8 hour/day
Chamber Volume :
- 1st Chamber : 2.5 m³
- Mixing Room : 0.5 m³
- Second Chamber : 1.2 m³
Incinerator Dimension (Outter) : L:360 X W:150 X H:220 cm
Burner :
- 1st Burner : 10 – 15 liter / hour, Light Oil Burner, Qty : 1 unit
- 2nd Burner : 10 –20 liter / hour, Light Oil Burner, Qty : 1 unit
Motor 220V / 50 Hz/ 1 Phase: 150-250 Watt x 2 : 500 Watt
Chamber Temperature :
- 1st Chamber : 600 - 800°C
- 2nd Chamber : 800- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exhaust Stack :
- Diameter : 450mm (1st Stack/Scrubber), Ø250 mm (2nd Stack)
- Height : ±14 m.from ground level
- Sampling Port Ø3”
- Coating : High Temp.Paint
Insulation and Refractory Construction Materials :
- Fire Brick : Fire Brick SK 34
- Castable : CAJ-14
- Ceramic Fibre, 128 kg/m³
- Rockwool,60 kg/m³
- Glaswool, 20 kg/m³
- Bottom : Insulating Brick
Shell & Structure Material Chamber :
- Shell Plate thickness 4 mm ,Mild Steel
- Joint Flange thickness 12 mm
- Burner Port thickness 8 mm
- Plenum Plate thickness 3 mm
- Structure UNP 80 & UNP 50
- Lifter thickness 12 mm
- Coating : Epoxy Paint
FDF Blower : Sentrifugal 4", 550Watt , 3000rpm : 2 unit (1100Watt)
atau sentrifugal 8-25 mmAg, Capacity 25 m3/min, Qty 2 unit RB1/RB2
Diesel Oil Fuel Consumption : average 35 liter / hour
Fuel Tank :
- Tank Capacity 500 ltr
- Material Tank : Mild Steel plate t. 4 mm
- Level Control
- Drain Port
Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt
Power Requirement : 2.2 kW / 380 Volt / 1phase
Control System :
- ELC
- Temperature Control : Digital
- Thermocouple : Type – K.
- Limit Switch
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 6 x 9 m
Emission Quality According to Government Regulation for the
following :
- Smokeless
- CO < 100 mg/Nm3
- NO2 < 300 mg/Nm3
- Opacity < 10%

Web Officer

Kami siap membantu Anda

Karya Mitra Usaha

Ruko Taman Yasmin Sektor VI No. 134,
Jl. Ring Road Utara, Curug Mekar, Bogor

  • Tel: (+62) 251-754 3316
  • Fax: (+62) 251-754 3281
  • Email: karyamitrausaha@yahoo.com
  • Website: www.incinerator.co.id